The FDUM series of ducted systems are a quiet and compact solution for heating and cooling multiple rooms. Coming in 5.0kW and 5.6kW capacities, the FDUM series incorporates a range of convenient features and functions including Automatic Mode, High Power Mode, Silent Mode and a range of timer and scheduling functions making them the perfect climate solution for smaller Aussie homes.


POWER: Single Phase  | AVAILABLE IN: Reverse Cycle

CAPACITIES: 5.0kW | 5.6kW

Key features

  • Silent operation
  • High power mode for rapid cooling and heating
  • Weekly / Sleep timers
  • Dry operation to reduce humidity
  • Economy mode

SELECT A CAPACITY TO VIEW SPECIFICATIONS

Single Phase
Specifications
SELECTED MODEL: SRK20ZSA-W / DXK06ZSA-W
Capacity
COOLING:
HEATING:
Energy Labels
Hot
COOLING:
HEATING:
Average
COOLING:
HEATING:
Cold
COOLING:
HEATING:
Dimensions (HxWxD)
INDOOR:
OUTDOOR:
Energy Saving
Home Leave Operation

Maintains a moderate indoor temperature, avoiding extremely hot or cool temperatures. Suitable for when rooms are unoccupied for long periods of time.

Set Temperature Auto Return

Program a preferred set temperature that the unit will return to each time it is switched on. Requires RC-EXZ3A wired controller.

Economy Mode

Unit operates at slightly reduced capacity to reduce power consumption while maintaining a comfortable room temperature.

Comfort & Convenience
Dry Operation

Reduces humidity by removing moisture from the air without affecting indoor temperature.

Hi Power Operation

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.

Silent Operation

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

Night Setback

Designed for the colder seasons, this function ensures the room temperature is kept at around 10ËšC, even while unoccupied.

Weekly Timer

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

Sleep Timer

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

On/Off Timer

Set your unit to turn on and off once, at specific times, within a 24 hour period.

Air Flow
Air Filter

Traps and removes air borne dust particles and other allergens, providing you with clean air throughout your home.

Filter Sign

Alerts you to when the filter needs to be cleaned.

Outside Air Intake

Allocated outside air inlet connection available on indoor unit to provide fresh air into the room, avoiding the constant recycling of internal air. Requires separate outside air duct to be connected to indoor unit.

Automatic Fan Speed

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

Maintenance
Built-in Drain Pump

The built-in drain pump allows greater flexibility with installation, offering a perfect solution for applications with limited space.

Improved Serviceability

The fan unit (comprised of impeller and motor) is easily accessible from either the side or bottom of the unit and can be slid out for easy maintenance.

Self-Diagnostics

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

Auto Restart Function

If there is a temporary loss of power, when power is restored, the unit will automatically restart in the same operating mode it was in.

SELECT CONTROLLER TYPE FOR DETAILS:
RC-EXZ3A with Zone Function
Airzone Zoning Solution
RCN-KIT4-E2
Wi-Fi
Zone Control
Control different zones within your system, saving energy and reducing running costs*
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Dry Operation
Reduces humidity by removing moisture from the air without affecting indoor temperature.
Silent Operation
Set periods of time where the unit will operate with even further reduced noise levels.
Automatic Operation
Automatically selects heating or cooling function based on the current room conditions.
Sleep Timer
Set a pre-determined amount of time that your unit will operate for before switching off.
Weekly Timer
Set your unit to turn on and off up to 4 times each day of the week.

*Requires MHIAA zoning solution comprised of relay board and transformer (sold separately).

Download Manual

Airzone zoning solution offers the ultimate level of comfort by providing complete temperature control over each individual zone of your home as well giving you the option to turn un-used zones off – saving you energy.

Blueface – Main Controller

  • Intuitive, blacklit 3.5″ colour touch screen
  • Temperature control for up to 10 individual zones.
  • Turn zones On/Off
  • Adjust system mode settings (Cool, Heat, Auto and Dry)
  • Adjust user modes (Eco, Vacation, Stop, Comfort and Night)
  • 7 day timer scheduling
  • Sleep timer
  • Automatic update the system software via Wi-Fi
  • Available in black and white

 

Think – Zone Controller

  • E-ink screen with capacitive buttons (Wired or Wireless)
  • Adjust system mode settings (Cool, Heat, Auto and Dry)
  • Adjust user modes (Eco, Vacation, Stop, Comfort and Night)
  • 7 day timer scheduling
  • Sleep timer
  • Available in black and white

 

Lite – Zone Controller

  • Simplified zone temperature controller (Wired or Wireless)
  • Turn zone on/off
  • Set-point temperature control (accuracy: ±1oC, up to a limit of ±3oC)
  • Designed to be controlled via main controller or AirzoneCLOUD app. Perfect for childrens bedrooms or playrooms.
  • Available in black and white

Download Manual
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
Silent Operation
Set periods of time where the unit will operate with even further reduced noise levels.
On/Off Timer
Set your unit to turn on and off once within a 24 hour period.
Night Setback
Maintains room temperature during cold conditions, even when the room is unattended.
Child Lock
Disables the controller and prevents inadvertent changes to the control settings.
Sleep Timer
Set a pre-determined amount of time that your unit will operate for before switching off.
Weekly Timer
Set your unit to turn on and off up to 4 times each day of the week.

For more information on the functions available and how to access them on your remote control, please refer to your unit’s user manual.

Download Manual

Control your system using your smart device (iPhone, iPad) or internet browser via to easy to use AC Cloud Control app*.

  • Control the set temperature, operation mode and fan speed.
  • Control your system via your Google or Amazon smart speaker device.
  • Control your system using Voice Commands.
  • Set up ‘favourite’ scenes and activate them with a single tap.
  • Set your system to respond to the weather, you arriving home, calendar events + more**.
  • Receive instant notifications and email updates and create usage logs**.

*Wi-Fi control requires MH-RC-WIFI-1B Wi-Fi adaptor (sold separately)
**In conjunction with IFTTT and other apps (must be downloaded separately).

Note: Some functions for some air conditioners may not be available via AC Cloud Control app. On/Off timer, weekly timer and sleep timer are disabled if Wi-Fi accessory connected. Similar functions can be set via the AC Cloud application.

Download Manual
FDUM Series
Ducted Systems Brochure
FDUM Series
User Manual Airzone Controller (FDU, FDUA, FDUM, FDCA Series)
FDUM Series
User Manual Wi-Fi Control (MH-RC-WIFI-1B) FDCA, FDUA, FDUM, FDT, FDTC, FDE SERIES
FDUM Series
User Manual RCN-KIT4-E2 Wireless Kit Controller (FDUA, FDUM, FDCA Series)
FDUM Series
User Manual RC-EXZ3A Controller (FDCA, FDUA, FDUM, FDT, FDTC, FDE Series)

What Makes Mitsubishi Heavy Industries The Experts in Air?

Ultimate Customer Satisfaction

Backed by award-winning technology, effortless performance, and unparalleled product reliability, we are dedicated to ensuring your complete satisfaction at every touchpoint.

Reliability

Designed to perform in the most demanding environments on earth, we engineer our products to endure its harshest conditions, from scorching summers, ice-cold winters and everything in-between.

Superior Technology

With world-class engineering and product innovation in our DNA, we push the boundaries to develop technology that delivers optimal experience. You can depend on us to deliver comfort in your home year after year.

Commitment to Our Customers

Standing behind the quality of our products is our commitment to our customers and after sales service guarantees with comprehensive warranties providing you peace of mind.
5 Years Parts and Labour Warranty
Standing behind our products and highlighting our commitment to our customers, all our air-conditioning systems are backed by a full 5 year parts and labour warranty.

Request a Quote

Considering the FDUM series? Leave some details below and we’ll get an installer in your area to get in touch!

FAQ

What is the difference between Single Phase and Three Phase models of Ducted, Ceiling Suspended and Ceiling Cassette systems?
The power supply to the premises. A single phase has one power supply (standard) whereas a three phase has 3 power supplies. In general, residential premises use single phase and commercial premises use three phase, however three phase can be installed in your house. Each model is made to suit each application. To find out what application you require contact your local dealer.
What is the difference between High Static and Medium Static Ducted systems?
Static Pressure is the amount of pressure an AC unit needs to overcome friction. The longer the duct the more static you need. High Static ducted systems are suitable for larger houses with a longer duct range as they can produce more static pressure. Medium Static ducted systems are used in smaller/medium sized homes that have a shorter duct requirement.
What does the heating and cooling capacity (kW) mean?
The heating and cooling capacity of your AC is measured in kilowatts (kW). Kilowatts measure the amount of energy output that occurs during operation. AC units that have a larger kW capacity can heat or cool larger spaces.
What does reverse cycle mean?
A reverse cycle system will provide both heating and cooling options. This means that your air conditioner can be used all year round.
What is R32 refrigerant and what impact does it have on my energy bills?
R32 refrigerant is the next generation refrigerant that has a lower Global Warming Potential and offers amazing energy efficiency benefits. The R32 refrigerant needs less energy to achieve the desired temperature as it requires less refrigerant volume to operate.  This will lower the amount of electricity usage your AC contributes to your energy bills.
How can I ensure that my air conditioner is properly maintained to operate efficiently all year around?
To ensure your air conditioner works all year round you should regularly check, or have a technician check, for any blockages or obstructions in the drain pipes that run from your outdoor unit, clean the filters and ensure your air conditioner is regularly serviced.
Do I need a Ducted System in my house?
Depending on how many rooms you wish to heat or cool, and the size of your house, ducted air conditioners can be a more economical option over split systems. If you do not have roof space or room for ducting, ducted is not an option for your home.  To determine if you need a ducted system in your house contact your local MHI dealer who will help you make the right choice.
What size air conditioner do I typically need to meet the cooling and heating needs for my home?
A number of factors impact the size of the AC unit for your home. Factors such as building material, shading, structure, orientation, floor coverings and what your AC is required for will all impact the sizing of your AC. For the best advice on your room sizing needs contact your local dealer.
Who can I speak to about selecting the right air conditioner for my home?
Our local MHI dealers can answer all your questions and help you select the right air conditioner for your home. To find your local dealer click here.
I want to replace my old air conditioner. Should my replacement be the same size?
Depending on the age of your old air conditioner it is not always guaranteed that your replacement will be the same size. Your local MHI dealer will be able to clarify the perfect capacity size for your AC needs.
Where do I go to buy an MHI air conditioner?
Our air conditioners are available at a number of different retail or dealer outlets. To find your closest local stockist click here.
Where should I place my air conditioner in the room?
To select the best location in your house for your AC unit you will need to consider the shape and size of your room, the capacity of the unit and the piping length that connects the indoor and outdoor unit. Contact your local MHI dealer today and find the best place to install your air conditioner.
How long will it take to install an MHI air conditioner?
Depending on the unit you purchase the installation time will vary. Most split system air conditioners can be installed within a few hours. For Ducted systems this process is longer as there is more work needed. For the complete installation times and availabilities please contact your local MHI dealer.
What is the installation process if I’m building a new home?
When building new home installers can work with your builders to develop a time frame that will suit them both. We recommend contacting your local installer at the beginning of the project so that your builder and installer can meet your exact requirements. For more information on this process please contact your local MHI dealer directly.
Why is it important to hire a licensed installer and what type of license do they need in Australia?
The installation process for air conditioners involves both electrical and refrigeration work, which is why it is important to have a licensed installer. In Australia, only a registered ARCTICK (Australian Refrigeration Council) Installer and an A-grade electrician should be used. Your 5 year parts and labour warranty will be voided if your system is installed by an unlicensed installer.
I am buying a new ducted system to replace the old one that I currently have. Can I use the existing ducts with my new system?
To get the maximum efficiency out of your AC unit and to take advantage of the updated technology we recommend that when replacing your ducted system you also replace the existing ducts. Request a Quote to check with an MHIAA dealer/installer on ductwork to be sure.
TECHNICAL SPECIFICATIONS
ABCDEFG
1
SetFDUM50ZSXAWVHFDUM60ZSXAWVH
2
IndoorFDUM50VHFDUM60VH
3
OutdoorSRC50ZSXA-WSRC60ZSXA-W
4
Power source (Outdoor Unit)1 Phase 240V 50Hz
5
*Operation
data
Nominal Capacity (Range)Cooling T1kW5.0 (1.1-5.6)5.6 (1.1-6.3)
6
Heating H15.4 (0.6-6.3)6.7 (0.6-7.1)
7
Heating H24.84.8
8
Power consumptionCooling T1kW1.511.53
9
Heating H11.591.75
10
Maximum power consumptionkW2.92.9
11
Running currentCooling T1A6.96.8
12
Heating H17.27.8
13
Inrush current, maximum currentA5, 155, 15
14
EERCooling T13.313.64
15
COPHeating H13.393.83
16
Sound power level (JIS C9612)OutdoordB(A)6365
17
Sound pressure level (JIS C9612)IndoordB (A)P-Hi:37 Hi:32
Me:29 Lo:26
P-Hi:36 Hi:31
Me:28 Lo:25
18
Outdoor5254
19
External dimensions (HxWxD)Indoormm280x750x635280x950x635
20
Outdoor640x800(+71)x290640x800(+71)x290
21
Net weightIndoorkg2934
22
Outdoor4545
23
Supply air connectionmm170x680170x880
24
Return air connectionmm200x660200x860
25
External Static Pressure (max)Pa100100
26
AirflowIndoor (Cooling)l/sP-Hi: 217 Hi: 167 Me: 150 Lo: 133P-Hi:333 Hi:250 Me:217 Lo:167
27
Indoor (Heating)
28
Refrigerant (R32)Quantitykg1.31.3
29
Pre charged to pipe lengthm1515
30
Installation dataRefrigerant pipingLiquid linemmØ6.35Ø6.35
31
Gas lineØ12.7Ø12.7
32
Connection methodFlare Connection
33
Maximum pipe (one way) lengthm3030
34
Max vertical height diff. between O.U. and I.U.m20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
35
ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
36
Motion Sensor (Optional)LB-KIT2
37
Demand response (AS4755)Yes
38
Outdoor air temperature (upper, lower limits)CoolingC-15 to +46-15 to +46
39
HeatingC-20 to +20-20 to +20
40
* Operation data has been gathered in accordance with AS/NZS 3823 standards.