  • Reverse Cycle model
  • Air Outlet selection for ultimate airflow control
  • Clean air with Allergen Clear Filter
  • Hi Power mode for rapid heating and cooling
  • Optional Wi-Fi control
Energy Saving

Fuzzy Auto Mode

Using fuzzy logic algorithms, the unit determines the operating mode and temperature settings automatically and adjusts the inverter frequency.

Eco Mode

Unit operates at slightly reduced capacity to reduce power consumption while maintaining a comfortable room temperature.
Air Flow

Auto Louvre Mode

Depending on whether the unit is in heating or cooling mode this will automatically set the louvre at the optimum angle for even air distribution.

Memory Louvre

Set the louvre at the desired angle. Unit will automatically return the louvres to this position on every subsequent start up.

Up/Down Louvre Swing

The horizontal louvres will automatically swing up and down for even air distribution.

Air Outlet Selection

Select whether the airflow is distributed via the upper outlet, the lower outlet or both.
Clean Air

Self-Clean Operation

Dries the indoor unit and filter, preventing the growth of mould. Designed to be run regularly after use.

Photocatalytic Deodorizing Filter

Easy to clean filter that catches airborne allergens and particles before neutralising odour causing bacteria within them.

Removable Cover

Removable front cover allowing access for easy cleaning and maintenance.
Comfort & Convenience

Dry Operation

Reduces humidity by removing moisture from the air without effecting indoor temperature.

Hi Power Operation

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit. Note: For FDE, FDT, FDTC, FDUA, and FDUM series can only be enabled using the RC-EX3 wired controller.

Silent Operation

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

Night Setback

Designed for the colder seasons, this function ensures the room temperature is kept at around 10˚C, even while unoccupied.

Weekly Timer

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

Sleep Timer

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

On/Off Timer

Set your unit to turn on and off once, at specific times, within a 24 hour period. Unit will then turn on and off at the specified times every day.

Comfort Start-up

When using the ON-TIMER function, the unit will switch on slightly earlier than the SET time, to ensure the optimum temperature is reached at the ON TIME.

Child Lock

Lock the remote control to prevent little ones from changing functions and other settings. Useful for families with curious young children.
Maintenance

Microcomputer-Operated Defrosting

Automatically activated during low ambient temperatures to prevent the frosting of the outdoor heat exchanger.

Self-Diagnostics

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

Auto Restart Function

If there is a temporary loss of power, when power is restored, the unit will automatically restart in the same operating mode it was in.
Indoor SRF50ZMXA-S
Outdoor SRC50ZMXA-S
Power supply     1 Phase 220~240V 50Hz
CapacityØ Cooling T1 kW 5.0 (1.1~5.2)
Heating H1 6.0 (0.6~6.9)
Heating H2 5.91
InputØ Cooling T1 kW 1.390 (0.20~1.70)
Heating H1 1.540 (0.20~2.15)
Max running current   A 15
Energy label CoolingØ Stars 2.5
HeatingØ 3
EER Cooling T1   3.60
COP Heating H1   3.90
Heating H2   3.03
Sound power level (JIS C9612) Cooling(Outdoor) dB (A) 63
Heating(Outdoor) 62
Sound pressure level (JIS C9612)Ø Cooling(Indoor) dB(A) 46-42-35-32
Heating(Indoor) 47-41-39-33
Airflow Cooling(Indoor) L/s 192-160-123-110
Heating(Indoor) 200-167-157-127
External dimensions (HXWXD) Indoor mm 600x860x238
Outdoor 640x800(+71)x290
Net weight Indoor kg 19
Outdoor 45
Refrigerant piping Liquid line mm Ø6.35
Gas line Ø12.7
Connection method   Flare connection
Refrigerant R410A Quantity kg 1.5
Pe Charged To Pipe Length m 15
Clean filter     Enzyme & Photocatalytic Washable Deodorizing Filter
Wireless

Wireless remote control

  • Use the Mode button to select  from Cool, Heat, Dry, or Fan Only operation or let the unit do it automatically when you select Auto option.
  • Activate Hi Power mode to achieve the desired room temperature faster.
  • Activate Allergen Clear function with a simple click of a button. Run for approximately 90 minutes, this program is designed to eliminate the allergens commonly found in the room air and effectively lock them away from your airflow.
  • For maximum comfort, easily adjust Airflow Direction in your room by simply pressing U/D (up / down) button.
  • By combining a start timer with a stop timer, you can register up to 4 timer operations a day (max 28 per week). Once set, the Weekly Timer will faithfully start or stop the system at a specified time of the day repeatedly.
  • Use Child Lock function to disable the controller and prevent inadvertent changes to the control settings from the youngest members of the family.
  • Enable Night Setback to maintain your room temperature during cold conditions, even when the room is unattended.

For more information on the functions available and how to access them on your remote control, please refer to your unit’s user manual.

Wired

RCH-E3

 

  • With the ability to control up to 16 indoor units, RCH-E3 is intended for use in a setting where everyday users only need access to the basic functions.
  • With the RCH-E3 users can turn the air conditioner ON/OFF and control the mode, temperature and fan speed settings.

Note: All wired control options require the SC-BIKN2-E remote control interface sold separately.

RC-EX3

 

  • Enable Hi Power Operation which allows the unit to run continuously for 15 minutes to reach the desired room temperature quickly.
  • Easily adjust the fan speed of the unit.
  • Control the up/down flap swing of the unit. This function allows you to fix the up/down flap swing at your preferred angle for the continuous up/down swing. The next time you turn on your air conditioner the flap will return to the last position that it was in when the unit was stopped.

Note: All wired control options require the SC-BIKN2-E remote control interface sold separately.

RC-E5

 

  • Enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display.
  • Weekly Timer function is a standard inclusion. This allows users to set up to 28 different timers, on and off operations, in a week with 4 timer programs per day available.
  • The temperature of the room is controlled by the remote control sensor.

Note: All wired control options require the SC-BIKN2-E remote control interface sold separately.

Wi-Fi

Wi-Fi control

 

  • Turn the air conditioner on before you arrive home
  • Change how the system has been programmed if you will be arriving home late
  • Access the current room temperature of your home when you are at work or away from home.
  • Program the air conditioner with a calendar schedule in an easy and intuitive way.
  • Set the desired temperature, mode and fan speed.
  • Control both the left/right louvers and the up/down louvers.
  • The anti-frost function prevents the indoor temperature from reaching freezing point. By setting the  temperature on a special set point, the unit will turn off before the temperature of the room becomes too cold.

Note: Wi-Fi control is optional and requires IS-IR-WI-FI-1 Wi-Fi adaptor sold separately.