SCM100ZM-S, 10.0kW

Outdoor Unit SCM100ZM-S
Power supply Outdoor   1 Phase 230V 50Hz
CapacityØ Cooling T1 kW 10 (1.8~12.0)
Heating H1 kW 12 (1.5~13.5)
InputØ Cooling T1 kW 2.86
Heating H1 kW 2.93
EER Cooling T1   3.5
COP Heating H1   4.1
CurrentØ Cooling T1 A 12.4
Heating H1 A 12.8
Rec Circuit Breaker     32A
Sound power level (JIS C9612) Cooling(Outdoor) dB (A) 68
Heating(Outdoor) dB (A) 71
External dimensionsØ (HXWXD) mm 945x970x370
Net weight Outdoor kg 92
Refrigerant piping Liquid line mm Ø6.35 X 5
Gas line mm Ø9.52 X 5
Union mm (φ9.52→φ12.7, φ15.8) X 2
Connection method   Flare connection
Refrigerant R410A Volume kg 6
Pre-Charged m 50
Indoor Unit Combination SRK-ZMA kW 2.0, 2.5, 3.5, 5.0, *7.1
SRK-ZMXA kW 2.0, 2.5, 3.5, 5.0, 6.0
SRF-ZMXA kW 2.5, 3.5, 5.0
SRR-ZM kW 2.5, 3.5, 5.0, 6.0
FDTC-VF kW 2.5, 3.5, 5.0, 6.0
FDUM-VF kW 5.0
FDE-VG kW 5.0
Indoor Unit Connection     2* to 5 Units
Indoor Connection Capacity   kW 8.0 kW to 16.0kW
       
Note 1 Rated data is measured using SRK*ZJX indoor unit at an equilivant indoor/ outdoor capacity  
Note 2 Currently there is no energy labelling standard for this type of productØ