Skip to main content
 

FDUM Series

The FDUM series of ducted systems are a quiet and compact solution for heating and cooling multiple rooms. Coming in 5.0kW and 5.6kW capacities, the FDUM series incorporates a range of convenient features and functions including Automatic Mode, Hi Power Mode, Silent Mode and a range of timer and scheduling functions making them the perfect climate solution for smaller commercial applications.


POWER: Single Phase  | AVAILABLE IN: Reverse Cycle

CAPACITIES: 5.0kW | 5.6kW

Key features

  • Silent operation
  • High power mode
  • Weekly / Sleep timers
  • Dry operation to reduce humidity
  • Eco operation

SELECT A CAPACITY TO VIEW SPECIFICATIONS

Single Phase
Specifications
SELECTED MODEL: SRK20ZSA-W / DXK06ZSA-W
Capacity
COOLING:
HEATING:
Energy Labels
Hot
COOLING:
HEATING:
Average
COOLING:
HEATING:
Cold
COOLING:
HEATING:
Dimensions (HxWxD)
INDOOR:
OUTDOOR:
Energy Saving
Home Leave Operation

Maintains a moderate indoor temperature, avoiding extremely hot or cool temperatures. Suitable for when rooms are unoccupied for long periods of time.

Set Temperature Auto Return

Program a preferred set temperature that the unit will return to each time it is switched on. Requires RC-EXZ3A wired controller.

Economy Mode

Unit operates at slightly reduced capacity to reduce power consumption while maintaining a comfortable room temperature.

Comfort & Convenience
Automatic Operation

Automatically selects the required heating or cooling function based on the current room conditions and set temperature.

Dry Operation

Reduces humidity by removing moisture from the air without affecting indoor temperature.

Function Switch

Set two functions to operate automatically. Requires RC-EXZ3A wired controller and no other central controller to be connected.

Peak-Cut Timer

Set the capacity limit during peak billing times, minimising energy consumption and reducing running costs. Requires RC-EXZ3A wired controller.

Hi Power Operation

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.

Silent Operation

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

Weekly Timer

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

Sleep Timer

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

On/Off Timer

Set your unit to turn on and off once, at specific times, within a 24 hour period.

Air Flow
Filter Sign

Alerts you to when the filter needs to be cleaned.

Outside Air Intake

Allocated outside air inlet connection available on indoor unit to provide fresh air into the room, avoiding the constant recycling of internal air. Requires separate outside air duct to be connected to indoor unit.

Automatic Fan Speed

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

Maintenance
Built-in Drain Pump

The built-in drain pump allows greater flexibility with installation, offering a perfect solution for applications with limited space.

Improved Serviceability

The fan unit (comprised of impeller and motor) is easily accessible from either the side or bottom of the unit and can be slid out for easy maintenance.

Self-Diagnostics

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

Auto Restart Function

If there is a temporary loss of power, when power is restored, the unit will automatically restart in the same operating mode it was in.

SELECT CONTROLLER TYPE FOR DETAILS:
RC-EXZ3A with Zone Function
Airzone Zoning Solution
RCN-KIT4-E2
Wi-Fi
Zone Control
Control different zones within your system, saving energy and reducing running costs*
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Dry Operation
Reduces humidity by removing moisture from the air without affecting indoor temperature.
Silent Operation
Set periods of time where the unit will operate with even further reduced noise levels.
Automatic Operation
Automatically selects heating or cooling function based on the current room conditions.
Sleep Timer
Set a pre-determined amount of time that your unit will operate for before switching off.
Weekly Timer
Set your unit to turn on and off up to 4 times each day of the week.

*Requires MHIAA zoning solution comprised of relay board and transformer (sold separately).

Download Manual

Airzone zoning solution offers the ultimate level of comfort by providing complete temperature control over each individual zone of your home as well giving you the option to turn un-used zones off – saving you energy.

Blueface – Main Controller

  • Intuitive, blacklit 3.5″ colour touch screen
  • Temperature control for up to 10 individual zones.
  • Turn zones On/Off
  • Adjust system mode settings (Cool, Heat, Auto and Dry)
  • Adjust user modes (Eco, Vacation, Stop, Comfort and Night)
  • 7 day timer scheduling
  • Sleep timer
  • Automatic update the system software via Wi-Fi
  • Available in black and white

 

Think – Zone Controller

  • E-ink screen with capacitive buttons (Wired or Wireless)
  • Adjust system mode settings (Cool, Heat, Auto and Dry)
  • Adjust user modes (Eco, Vacation, Stop, Comfort and Night)
  • 7 day timer scheduling
  • Sleep timer
  • Available in black and white

 

Lite – Zone Controller

  • Simplified zone temperature controller (Wired or Wireless)
  • Turn zone on/off
  • Set-point temperature control (accuracy: ±1oC, up to a limit of ±3oC)
  • Designed to be controlled via main controller or AirzoneCLOUD app. Perfect for childrens bedrooms or playrooms.
  • Available in black and white

Download Manual
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
On/Off Timer
Set your unit to turn on and off once within a 24 hour period.
Child Lock
Disables the controller and prevents inadvertent changes to the control settings.
Night Setback
Maintains room temperature during cold conditions, even when the room is unattended.
Automatic Operation
Automatically selects heating or cooling function based on the current room conditions.

For more information on the functions available and how to access them on your remote control, please refer to your unit’s user manual.

Download Manual

Control your system using your smart device (iPhone, iPad) or internet browser via to easy to use AC Cloud Control app*.

  • Control the set temperature, operation mode and fan speed.
  • Control your system via your Google or Amazon smart speaker device.
  • Control your system using Voice Commands.
  • Set up ‘favourite’ scenes and activate them with a single tap.
  • Set your system to respond to the weather, you arriving home, calendar events + more**.
  • Receive instant notifications and email updates and create usage logs**.

*Wi-Fi control requires MH-RC-WIFI-1B Wi-Fi adaptor (sold separately)
**In conjunction with IFTTT and other apps (must be downloaded separately).

Note: some functions for some air conditioners may not be available via AC Cloud Control app. On/Off timer, weekly timer and sleep timer are disabled if Wi-Fi accessory connected. Similar functions can be set via the AC Cloud application.

Download Manual
FDUM Series
Ducted Systems Brochure
FDUM Series
User Manual Airzone Controller (FDU, FDUA, FDUM, FDCA Series)
FDUM Series
User Manual Wi-Fi Control (MH-RC-WIFI-1B) FDCA, FDUA, FDUM, FDT, FDTC, FDE SERIES
FDUM Series
User Manual RC-EXZ3A Controller (FDCA, FDUA, FDUM, FDT, FDTC, FDE Series)
FDUM Series
User Manual RCN-KIT4-E2 Wireless Kit Controller (FDUA, FDUM, FDCA Series)

What Makes Mitsubishi Heavy Industries The Experts in Air?

Ultimate Customer Satisfaction

Backed by award-winning technology, effortless performance, and unparalleled product reliability, we are dedicated to ensuring your complete satisfaction at every touchpoint.

Reliability

Designed to perform in the most demanding environments on earth, we engineer our products to endure its harshest conditions, from scorching summers, ice-cold winters and everything in-between.

Superior Technology

With world-class engineering and product innovation in our DNA, we push the boundaries to develop technology that delivers optimal experience. You can depend on us to deliver comfort in your home year after year.

Commitment to Our Customers

Standing behind the quality of our products is our commitment to our customers and after sales service guarantees with comprehensive warranties providing you peace of mind.
TECHNICAL SPECIFICATIONS
ABCDEFG
1
SetFDUM50ZSXAWVHFDUM60ZSXAWVH
2
IndoorFDUM50VHFDUM60VH
3
OutdoorSRC50ZSXA-WSRC60ZSXA-W
4
Power source (Outdoor Unit)1 Phase 240V 50Hz
5
*Operation
data
Nominal Capacity (Range)Cooling T1kW5.0 (1.1-5.6)5.6 (1.1-6.3)
6
Heating H15.4 (0.6-6.3)6.7 (0.6-7.1)
7
Heating H24.84.8
8
Power consumptionCooling T1kW1.511.53
9
Heating H11.591.75
10
Maximum power consumptionkW2.92.9
11
Running currentCooling T1A6.96.8
12
Heating H17.27.8
13
Inrush current, maximum currentA5, 155, 15
14
EERCooling T13.313.64
15
COPHeating H13.393.83
16
Sound power level (JIS C9612)OutdoordB(A)6365
17
Sound pressure level (JIS C9612)IndoordB (A)P-Hi:37 Hi:32
Me:29 Lo:26
P-Hi:36 Hi:31
Me:28 Lo:25
18
Outdoor5254
19
External dimensions (HxWxD)Indoormm280x750x635280x950x635
20
Outdoor640x800(+71)x290640x800(+71)x290
21
Net weightIndoorkg2934
22
Outdoor4545
23
Supply air connectionmm170x680170x880
24
Return air connectionmm200x660200x860
25
External Static Pressure (max)Pa100100
26
AirflowIndoor (Cooling)l/sP-Hi: 217 Hi: 167 Me: 150 Lo: 133P-Hi:333 Hi:250 Me:217 Lo:167
27
Indoor (Heating)
28
Refrigerant (R32)Quantitykg1.31.3
29
Pre charged to pipe lengthm1515
30
Installation dataRefrigerant pipingLiquid linemmØ6.35Ø6.35
31
Gas lineØ12.7Ø12.7
32
Connection methodFlare Connection
33
Maximum pipe (one way) lengthm3030
34
Max vertical height diff. between O.U. and I.U.m20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
35
ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
36
Motion Sensor (Optional)LB-KIT2
37
Demand response (AS4755)Yes
38
Outdoor air temperature (upper, lower limits)CoolingC-15 to +46-15 to +46
39
HeatingC-20 to +20-20 to +20
40
* Operation data has been gathered in accordance with AS/NZS 3823 standards.

Request a Quote

Leave some details and we'll get an installer to get in touch!