Skip to main content
 

FDUA Series

The FDUA series of ducted air conditioning systems are a quiet and discreet solution for heating and cooling multiple rooms. Ranging from 10.0kW up to 20kW, the FDUA series incorporates a range of convenient features and functions including Automatic Mode, Hi Power Mode, Silent Mode and a range of timer and scheduling functions making them the perfect climate solution for a range of commercial applications.


POWER: Single Phase & Three Phase  | AVAILABLE IN: Reverse Cycle

CAPACITIES: 10.0kW | 12.1kW | 12.5kW | 14.0kW | 16.0kW | 20.0kW | 23.5kW

Key features

  • High Power Mode
  • Weekly & Sleep timers
  • Silent operation
  • Dry operation to reduce humidity
  • Eco operation
Australia's Best Ducted
Air-Conditioner

The FDUA series has been named by ProductReview, Australia’s No.1 and most comprehensive consumer opinion site, as the best ducted air-conditioning system in their 2024 awards.

producreview best ducted system air-conditioner 2024 awards fdua
 

SELECT A CAPACITY TO VIEW SPECIFICATIONS

Single Phase
THREE PHASE
Specifications
SELECTED MODEL: SRK20ZSA-W / DXK06ZSA-W
Capacity
COOLING:
HEATING:
Energy Labels
Hot
COOLING:
HEATING:
Average
COOLING:
HEATING:
Cold
COOLING:
HEATING:
Dimensions (HxWxD)
INDOOR:
OUTDOOR:
Energy Saving
Home Leave Operation

Maintains a moderate indoor temperature, avoiding extremely hot or cool temperatures. Suitable for when rooms are unoccupied for long periods of time.

Set Temperature Auto Return

Program a preferred set temperature that the unit will return to each time it is switched on. Requires RC-EXZ3A wired controller.

Economy Mode

Unit operates at slightly reduced capacity to reduce power consumption while maintaining a comfortable room temperature.

Comfort & Convenience
Automatic Operation

Automatically selects the required heating or cooling function based on the current room conditions and set temperature.

Dry Operation

Reduces humidity by removing moisture from the air without affecting indoor temperature.

Function Switch

Set two functions to operate automatically. Requires RC-EXZ3A wired controller and no other central controller to be connected.

Peak-Cut Timer

Set the capacity limit during peak billing times, minimising energy consumption and reducing running costs. Requires RC-EXZ3A wired controller.

Hi Power Operation

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.

Silent Operation

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

Weekly Timer

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

Sleep Timer

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

On/Off Timer

Set your unit to turn on and off once, at specific times, within a 24 hour period.

Air Flow
Filter Sign

Alerts you to when the filter needs to be cleaned.

Outside Air Intake

Allocated outside air inlet connection available on indoor unit to provide fresh air into the room, avoiding the constant recycling of internal air. Requires separate outside air duct to be connected to indoor unit.

Automatic Fan Speed

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

Maintenance
Built-in Drain Pump

The built-in drain pump allows greater flexibility with installation, offering a perfect solution for applications with limited space.

Improved Serviceability

The fan unit (comprised of impeller and motor) is easily accessible from either the side or bottom of the unit and can be slid out for easy maintenance.

Self-Diagnostics

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

SELECT CONTROLLER TYPE FOR DETAILS:
RC-EXZ3A/D with Zone Function
Airzone Zoning Solution
RCN-KIT4-E2
Wi-Fi
Zone Control
Control different zones within your system, saving energy and reducing running costs*
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Dry Operation
Reduces humidity by removing moisture from the air without affecting indoor temperature.
Silent Operation
Set periods of time where the unit will operate with even further reduced noise levels.
Automatic Operation
Automatically selects heating or cooling function based on the current room conditions.
Sleep Timer
Set a pre-determined amount of time that your unit will operate for before switching off.
Weekly Timer
Set your unit to turn on and off up to 4 times each day of the week.

*Requires MHIAA zoning solution comprised of relay board and transformer (sold separately).

*RC-EXZ3A Controller suitable for use to control up to 4 individual zones

*RC-EXZ3D Controller suitable for use to control up to 8 individual zones

Download Manual

Airzone zoning solution offers the ultimate level of comfort by providing complete temperature control over each individual zone of your home as well giving you the option to turn un-used zones off – saving you energy.

Blueface – Main Controller

  • Intuitive, blacklit 3.5″ colour touch screen
  • Temperature control for up to 10 individual zones.
  • Turn zones On/Off
  • Adjust system mode settings (Cool, Heat, Auto and Dry)
  • Adjust user modes (Eco, Vacation, Stop, Comfort and Night)
  • 7 day timer scheduling
  • Sleep timer
  • Automatic update the system software via Wi-Fi
  • Available in black and white

 

Think – Zone Controller

  • E-ink screen with capacitive buttons (Wired or Wireless)
  • Adjust system mode settings (Cool, Heat, Auto and Dry)
  • Adjust user modes (Eco, Vacation, Stop, Comfort and Night)
  • 7 day timer scheduling
  • Sleep timer
  • Available in black and white

 

Lite – Zone Controller

  • Simplified zone temperature controller (Wired or Wireless)
  • Turn zone on/off
  • Set-point temperature control (accuracy: ±1oC, up to a limit of ±3oC)
  • Designed to be controlled via main controller or AirzoneCLOUD app. Perfect for childrens bedrooms or playrooms.
  • Available in black and white

Download Manual
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
Silent Operation
Set periods of time where the unit will operate with even further reduced noise levels.
On/Off Timer
Set your unit to turn on and off once within a 24 hour period.
Child Lock
Disables the controller and prevents inadvertent changes to the control settings.
Night Setback
Maintains room temperature during cold conditions, even when the room is unattended.
Sleep Timer
Set a pre-determined amount of time that your unit will operate for before switching off.
Weekly Timer
Set your unit to turn on and off up to 4 times each day of the week.

For more information on the functions available and how to access them on your remote control, please refer to your unit’s user manual.

Download Manual

Control your system using your smart device (iPhone, iPad) or internet browser via to easy to use AC Cloud Control app*.

  • Control the set temperature, operation mode and fan speed.
  • Control your system via your Google or Amazon smart speaker device.
  • Control your system using Voice Commands.
  • Set up ‘favourite’ scenes and activate them with a single tap.
  • Set your system to respond to the weather, you arriving home, calendar events + more**.
  • Receive instant notifications and email updates and create usage logs**.

*Wi-Fi control requires MH-RC-WIFI-1B Wi-Fi adaptor (sold separately)
**In conjunction with IFTTT and other apps (must be downloaded separately).

Note: some functions for some air conditioners may not be available via AC Cloud Control app. On/Off timer, weekly timer and sleep timer are disabled if Wi-Fi accessory connected. Similar functions can be set via the AC Cloud application.

Download Manual
FDUA Series
Ducted Systems Brochure
FDUA Series
User Manual Airzone Controller (FDU, FDUA, FDUM, FDCA Series)
FDUA Series
User Manual RCN-KIT4-E2 Wireless Kit Controller (FDUA, FDUM, FDCA Series)
FDUA Series
User Manual Wi-Fi Control (MH-RC-WIFI-1B) FDCA, FDUA, FDUM, FDT, FDTC, FDE SERIES
FDUA Series
User Manual RC-EXZ3A Controller (FDCA, FDUA, FDUM, FDT, FDTC, FDE Series)
FDUA Series
User Manual RC-E5 Controller (FDCA, FDUA, FDUM, FDT, FDTC, FDE Series)
FDUA Series
User Manual RCH-E3 Controller (FDUA, FDUM, FDCA, FDT, FDTC, FDE Series)
FDUA Series
RC-EXZ3D User Manual

What Makes Mitsubishi Heavy Industries The Experts in Air?

Ultimate Customer Satisfaction

Backed by award-winning technology, effortless performance, and unparalleled product reliability, we are dedicated to ensuring your complete satisfaction at every touchpoint.

Reliability

Designed to perform in the most demanding environments on earth, we engineer our products to endure its harshest conditions, from scorching summers, ice-cold winters and everything in-between.

Superior Technology

With world-class engineering and product innovation in our DNA, we push the boundaries to develop technology that delivers optimal experience. You can depend on us to deliver comfort in your home year after year.

Commitment to Our Customers

Standing behind the quality of our products is our commitment to our customers and after sales service guarantees with comprehensive warranties providing you peace of mind.
5 Years Parts and Labour Warranty
Standing behind our products and highlighting our commitment to our customers, all our air-conditioning systems are backed by a full 5 year parts and labour warranty.
TECHNICAL SPECIFICATIONS
ABCDEFGHIJKLMNOPQRSTUVWXY
1
1 phaseSetFDUA100AVNPWVHFDUA100AVNAWVHFDUA125VNPWVHFDUA125AVNPWVHFDUA125AVNXWVHFDUA140AVNXWVHFDUA160AVNXWVH3 phaseSetFDUA100AVSAWVHFDUA125AVSXWVHFDUA140AVSXWVHFDUA160AVSAWVHFDUA200AVSAWVHFDUA250AVSAWVH
2
IndoorFDUA100VHFDUA100VHFDUA125VHFDUA125VHFDUA125VHFDUA140VHFDUA160VHIndoorFDUA100VHFDUA125VHFDUA140VHFDUA160VHFDUA200VHFDUA250VH
3
OutdoorFDCA100VNP-WFDCA100VNA-WFDC125VNP-WFDCA125VNP-WFDCA125VNX-WFDCA140VNX-WFDCA160VNX-WOutdoorFDCA100VSA-WFDCA125VSX-WFDCA140VSX-WFDCA160VSA-WFDCA200VSA-WFDCA250VSA-W
4
Power source (Outdoor Unit)1 Phase 240V 50HzPower source (Outdoor Unit)3 Phase 380-415V 50Hz
5
*Operation dataNominal Capacity (Range)Cooling T1kW10 (2.1 -10.2)10.0 (4.0-11.2)12.1 (5.0-12.1)12.1 (5.0-12.1)12.5 (5.0-14.0)14.0 (5.0-14.5)16.0 (5.0-17.0)*Operation dataNominal Capacity (Range)Cooling T1kW10.0 (4.0-11.2)12.5 (5.0-14.0)14.0 (5.0-14.5)16.0 (6.9-20.0)20.0 (6.9-28.0)23.5 [ 6.9(Min.) - 28.0(Max.)]
6
Heating H110 (1.7 - 10.4)11.2 (4.0-12.5)12.1 (4.0-13.3)12.1 (4.0-13.3)14.0 (4.0-17.0)16.0 (4.0-18.0)18.0 (4.0-21.0)Heating H111.2 (4.0-12.5)14.0 (4.0-18.0)16.0 (4.0-18.0)18.0 (5.5-22.4)22.4(5.5-31.5)28.0 [ 5.5(Min.) - 31.5(Max.)]
7
Heating H27.6107.97.914.215.515Heating H21014.215.516.12121.1
8
Power consumptionCooling T1kW2.993.053.853.853.834.025Power consumptionCooling T1kW3.053.834.024.685.787.7
9
Heating H12.572.873.283.283.684.195Heating H12.873.684.194.65.447.7
10
Maximum power consumptionkW4.466.44.754.756.135.777.1Maximum power consumptionkW10.27.667.2611.211.211.2
11
Running currentCooling T1A13.214.716.216.21717.822Running currentCooling T1A4.76.46.77.59.112
12
Heating H111.41413.813.816.318.622Heating H14.46.26.97.58.612
13
Inrush current, maximum currentA5, 195, 265, 205, 205, 295, 305, 30Inrush current, maximum currentA5, 175, 185, 195, 245, 275, 27
14
EERCooling T13.343.283.143.143.263.483.16EERCooling T13.283.263.483.423.463.16
15
COPHeating H13.893.93.693.693.83.823.6COPHeating H13.93.83.823.914.123.67
16
Sound power level (JIS C9612)OutdoordB(A)68697373686969Sound power level (JIS C9612)OutdoordB(A)696869737373
17
Sound pressure level (JIS C9612)IndoordB (A)P-Hi:43 Hi:42 Me:40 Lo:37P-Hi:43 Hi:42 Me:40 Lo:37P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:48 Hi:47 Me:43 Lo:38P-Hi : 48 Hi : 47 Me : 43 Lo : 41Sound pressure level (JIS C9612)IndoordB (A)P-Hi:43 Hi:42 Me:40 Lo:37P-Hi:46 Hi:44 Me:42 Lo:38P-Hi:48 Hi:47 Me:43 Lo:38P-Hi:48 Hi:47 Me:43 Lo:41P-Hi:52 Hi:50 Me:47 Lo:45P-Hi : 52 Hi : 50 Me : 47 Lo : 45
18
Outdoor56555757545454Outdoor555454585858
19
External dimensions (HxWxD)Indoormm398x1150(+86)x650398x1150(+86)x650398x1150(+86)x650398x1150(+86)x650398x1150(+86)x650398x1450x930398 × 1450 × 930External dimensions (HxWxD)Indoormm398x1150(+86)x650398x1150(+86)x650398x1450x930398x1450x930379x1600(+85)x893379x1600(+85)x893
20
Outdoor750 × 880(+88) × 340845x970x370845x970x370845x970x3701300x970x3701300x970x3701300 × 970 × 370Outdoor845x970x3701300x970x3701300x970x3701505x970x3701505x970x3701505x970x370
21
Net weightIndoorkg52525252526666Net weightIndoorkg545266668888
22
Outdoor57777373979797Outdoor789999145145145
23
Supply air connectionmm348x898348x898348x898348x898348x898298x1064298x1064Supply air connectionmm348x898348x898298x1064298x1064250x1450250x1450
24
Return air connectionmm348x898348x898348x898348x898348x8982 X φ4002 X φ400Return air connectionmm348x898348x8982 X φ4002 X φ400250x1450250x1450
25
External Static Pressure (max)Pa200200200200200150150External Static Pressure (max)Pa200200150150200200
26
AirflowIndoor (Cooling)l/sP-Hi:650 Hi:600 Me:550 Lo:483P-Hi:650 Hi:600 Me:550 Lo:483P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:1000 Hi:867 Me:733 Lo:600P-Hi : 1000 Hi : 867 Me : 733 Lo : 683AirflowIndoor (Cooling)l/sP-Hi:650 Hi:600 Me:550 Lo:483P-Hi:717 Hi:650 Me:600 Lo:500P-Hi:1000 Hi:867 Me:733 Lo:600
P-Hi:1000 Hi:866 Me:733 Lo:683
P-Hi:1333 Hi:1200 Me:1067 Lo:933P-Hi:1333 Hi:1200 Me:1067 Lo:933
27
Indoor (Heating)P-Hi : 1000 Hi : 867 Me : 733 Lo : 600Indoor (Heating)
P-Hi:1000 Hi:866 Me:733 Lo:600
28
Refrigerant (R32)Quantitykg1.73.32.252.25444Refrigerant (R32)Quantitykg3.3445.15.15.1
29
Pre charged to pipe length
m15301515303030
Pre charged to pipe length
m303030303030
30
Installation dataRefrigerant pipingLiquid linemm**Ø6.35**Ø6.35Ø9.52Ø9.52Ø9.52Ø9.52Ø9.52Installation dataRefrigerant pipingLiquid linemmØ9.52Ø9.52Ø9.52Ø12.7Ø12.7Ø12.7
31
Gas lineØ15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Gas lineØ15.88Ø15.88Ø15.88Ø22.22 , Ø25.4 or Ø28.58Ø22.22 , Ø25.4 or Ø28.58Ø22.22 , Ø25.4 or Ø28.58
32
Connection methodFlare ConnectionConnection methodFlare ConnectionLiquid : Flare / Gas : Brazing
33
Maximum pipe (one way) lengthm30503030100100100Maximum pipe (one way) lengthm50100100**70**70**70
34
Max vertical height diff. between O.U. and I.U.m
20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
***50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
Max vertical height diff. between O.U. and I.U.m
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
***50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
35
ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2
36
Safety Pan (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)UA-SP2-E (Optional)NANASafety pan (Optional)UA-SP2-E (Optional)NANANANA
37
Motion Sensor (Optional)LB-KIT2Motion Sensor (Optional)LB-KIT2
38
Demand response (AS4755)NoYesNoYesYesYesYesDemand response (AS4755)YesYesYesYesYesYes
39
Outdoor air temperature (upper, lower limits)CoolingC-15 to 46-15 to 50-15 to 46-15 to 46-15 to 50-15 to 50-15 to 50Outdoor air temperature (upper, lower limits)CoolingC-15 to 50-15 to 50-15 to 50-15 to 50-15 to 50-15 to 50
40
HeatingC-15 to 20-20 to 20-15 to 20-15 to 20-20 to 20-20 to 20-20 to 20HeatingC-20 to 20-20 to 20-20 to 20-20 to 20-20 to 20-20 to 20
41
42
* Operation data are are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Page xxx* Operation data are conducted in accordance with AS/NZS 3823 standard. For testing conditions please refer to Pagexxx
43
44
**Reducer set Ø9.52 --> Ø6.35 is included in the outdoor unit as accessory for FDCA100VNP-W.** Maximum 70m(Gas piping:φ25.4 or φ28.58), Maximum 35m(Gas piping:φ22.22)
45
***Max.30m (Outdoor unit is higher & Outdoor air temperature > 43ËšC)
*** Max.30m (Outdoor unit is higher & Outdoor air temperature > 43ËšC)

Request a Quote